The load/span tables
shown in this Guide are derived from large scale tests using full panels
to simulate actual service conditions (at a reference temperature of 77°
F). These tests include two span vacuum box test and three point load
tests.
|
|||
|
|
|||
| The load/span tables
shown in this Guide are developed using the following maximum deflections
limits and Factors of Safety (FOS), unless otherwise noted: Panel Roofing: Positive Loads: Deflection: L/60, FOS:2.5 Negative Loads: Deflection: L/60, FOS: 1.88 Panel Siding: Wind Loads: Deflection: L/30, FOS:1.88 Roof Deck: Dead + Live Loads: Deflection: L/180, FOS:2.5 Uplift Loads: Deflection: L/18000, FOS:1.88 The load/span tables are to be used as a guide only as specific environmental conditions are not considered. Specific applications should be verified by a registered Professional Engineer. |
|||
|