4
3/16 RIB
|
 |
|
| |
| ROOFING:
POSITIVE LOADS |
| SPAN |
Uniform
Loads,
PSF |
SERIES |
| FR200 |
FR300 |
FR400 |
| SINGLE
|
20 |
3'8" |
4'0" |
4'3" |
| TWO
|
4'11" |
5'5" |
5'8" |
| THREE
|
4'6" |
5'0" |
5'3" |
| SINGLE
|
25 |
3'5" |
3'9" |
3'11" |
| TWO
|
4'7" |
5'0" |
5'3" |
| THREE
|
4'2" |
4'7" |
4'10" |
| SINGLE
|
30 |
3'2" |
3'6" |
3'8" |
| TWO
|
4'3" |
4'8" |
4'11" |
| THREE
|
3'11" |
4'4" |
4'7" |
| SINGLE
|
35 |
3'0" |
3'4" |
3'6" |
| TWO
|
4'1" |
4'6" |
4'8" |
| THREE
|
3'9" |
4'1" |
4'4" |
| SINGLE
|
40 |
2'11" |
3'2" |
3'4" |
| TWO
|
3'11" |
4'3" |
4'6" |
| THREE
|
3'7" |
3'11" |
4'2" |
| SINGLE
|
50 |
2'8" |
2'11" |
3'1" |
| TWO
|
3'7" |
4'0" |
4'2" |
| THREE
|
3'4" |
3'8" |
3'10" |
|
| |
| |
ROOFING:
NEGATIVE LOADS
Fasteners required at every other corrugation |
| SPAN |
Uniform
Loads,
PSF |
SERIES |
| FR200 |
FR300 |
FR400 |
| SINGLE
|
20 |
3'8" |
4'0" |
4'3" |
| TWO
|
4'11" |
5'5" |
5'0" |
| THREE
|
4'6" |
5'0" |
5'3" |
| SINGLE
|
25 |
3'5" |
3'9" |
3'11" |
| TWO
|
4'7" |
5'0" |
5'3" |
| THREE
|
4'2" |
4'7" |
4'10 |
| SINGLE
|
30 |
3'2" |
3'6" |
3'8" |
| TWO
|
4'3" |
4'8" |
4'11" |
| THREE
|
3'11" |
4'4" |
4'7" |
| SINGLE
|
35 |
3'0" |
3'4" |
3'6" |
| TWO
|
4'1" |
4'6" |
4'8" |
| THREE
|
3'9" |
4'1" |
4'4" |
| SINGLE
|
40 |
2'11" |
3'2" |
3'4" |
| TWO
|
3'11" |
4'3" |
4'6" |
| THREE
|
3'7" |
3'11" |
4'2" |
| SINGLE
|
50 |
2'8" |
2'11" |
3'1" |
| TWO
|
3'7" |
4'0" |
4'2" |
| THREE
|
3'4" |
3'8" |
3'10" |
|
| |
SIDING:
WIND LOADS
Fasteners required at every other corrugation |
| SPAN |
Uniform
Loads,
PSF |
SERIES |
| FR200 |
FR300 |
FR400 |
| SINGLE
|
20 |
4'7" |
5'1" |
5'4" |
| TWO
|
6'2" |
6'10" |
7'2" |
| THREE
|
5'8" |
6'3"
|
6'7" |
| SINGLE
|
25 |
4'3" |
4'8" |
4'11" |
| TWO
|
5'9" |
6'4" |
6'8" |
| THREE
|
5'3" |
5'10" |
6'2" |
| SINGLE
|
30 |
4'0" |
4'5" |
4'8" |
| TWO
|
5'5" |
5'11" |
6'3" |
| THREE
|
5'0" |
5'6" |
5'9" |
| SINGLE
|
35 |
3'10" |
4'2" |
4'5" |
| TWO
|
5'1" |
5'8" |
5'11" |
| THREE
|
4'9" |
5'2" |
5'6" |
| SINGLE
|
40 |
3'8" |
4'0" |
4'3" |
| TWO
|
4'11" |
5'5" |
5'8" |
| THREE
|
4'6" |
5'0" |
5'3" |
| SINGLE
|
50 |
3'5" |
3'9" |
3'11" |
| TWO
|
4'3" |
5'0" |
5'3" |
| THREE
|
4'2" |
4'7" |
4'10" |
|
| Contact Enduro for
SERIES FM Loads/Span Data |
| |
|
Load/Span Tables are
based on full scale tests that consider three design parameters:
- Critical bending
moment at actual panel failure
- Flexural stiffness
- Pullover force
per fastener of the panel section.
Table values are based
upon:
- Roofing:
Deflection l/60, FOS 2.5+, 1.88-
- Siding:
Deflection L/30 FOS 1.88
|
| |
|
|
| |
|
|
| |
|
The load/span tables
shown in this Guide are derived from large scale tests using full panels
to simulate actual service conditions (at a reference temperature of 77°
F). These tests include two span vacuum box test and three point load
tests.
Each span shown in the load/span tables represents the most conservative
span derived when the panel is assessed using the following parameters:
Design Parameters
- Critical bending
moment at actual panel failure;
- Flexural stiffness
factor, EI, (where E is the flexural
modulus of elasticity and I is the moment of inertia of
the panel section); and
- Pullover force
resistance per fastener.
|
|
|
| |
The load/span tables
shown in this Guide are developed using the following maximum deflections
limits and Factors of Safety (FOS), unless otherwise noted:
Panel Roofing:
Positive Loads: Deflection: L/60, FOS:2.5
Negative Loads: Deflection: L/60, FOS: 1.88
Panel Siding:
Wind Loads: Deflection: L/30, FOS:1.88
Roof Deck:
Dead + Live Loads: Deflection: L/180, FOS:2.5 Uplift Loads: Deflection:
L/18000, FOS:1.88
The load/span tables are to be used as a guide only as specific environmental
conditions are not considered.
Specific applications should be verified by a registered Professional Engineer.
|