|
|
R-PANEL
|
 |
|
| |
| ROOFING:
POSITIVE LOADS |
| SPAN |
Uniform
Loads,
PSF |
SERIES |
| FR200 |
FR300 |
FR400 |
| SINGLE
|
20 |
5'5" |
6'2" |
6'6" |
| TWO
|
5'9" |
7'8" |
8'9" |
| THREE
|
6'5" |
7'89" |
8'1" |
| SINGLE
|
25 |
5'0" |
5'9" |
6'1" |
| TWO
|
5'1" |
6'11" |
7'9" |
| THREE
|
5'9" |
7'1" |
7'6" |
| SINGLE
|
30 |
4'8" |
5'5" |
5'8" |
| TWO
|
4'8" |
6'3" |
7'1" |
| THREE
|
5'3" |
6'8" |
7'1" |
| SINGLE
|
35 |
4'4" |
5'1" |
5'5" |
| TWO
|
4'4" |
5'10" |
6'7" |
| THREE
|
4'10" |
6'4" |
6'8" |
| SINGLE
|
40 |
4'0" |
4'11" |
5'2" |
| TWO
|
4'0" |
5'5" |
6'2" |
| THREE
|
4'6" |
6'1" |
6'5" |
| SINGLE
|
50 |
3'7" |
4'6" |
4'10" |
| TWO
|
3'7" |
4'10" |
5'6" |
| THREE
|
4'0" |
5'5" |
5'11" |
|
| |
| |
ROOFING:
NEGATIVE LOADS
Fasteners required at every other corrugation |
| SPAN |
Uniform
Loads,
PSF |
SERIES |
| FR200 |
FR300 |
FR400 |
| SINGLE
|
20 |
5'5" |
6'2" |
6'6" |
| TWO
|
6'7" |
8'3" |
8'9" |
| THREE
|
6'8" |
7'8" |
8'1" |
| SINGLE
|
25 |
5'0" |
5'9" |
6'1" |
| TWO
|
5'11" |
7'8" |
8'2" |
| THREE
|
6'2" |
7'1" |
7'6" |
| SINGLE
|
30 |
4'9" |
5'5" |
5'8" |
| TWO
|
5'5" |
7'3" |
7'8" |
| THREE
|
5'10" |
6'8" |
7'1" |
| SINGLE
|
35 |
4'6" |
5'1" |
5'5" |
| TWO
|
4'10" |
6'9" |
7'3" |
| THREE
|
5'6" |
6'4" |
6'8" |
| SINGLE
|
40 |
4'3" |
4'11" |
5'2" |
| TWO
|
4'3 |
6'3" |
6'11" |
| THREE
|
4'10" |
6'1" |
6'5" |
| SINGLE
|
50 |
4'0" |
4'6"' |
4'10" |
| TWO
|
3'4" |
5'1" |
5'11" |
| THREE
|
3'10" |
5'7" |
5'11" |
|
| |
SIDING:
WIND LOADS
Fasteners required at every other corrugation |
| SPAN |
Uniform
Loads,
PSF |
SERIES |
| FR200 |
FR300 |
FR400 |
| SINGLE
|
20 |
6'7" |
7'9" |
8'3" |
| TWO
|
6'7" |
8'11" |
10'1" |
| THREE
|
7'5" |
9'5"
|
9'10" |
| SINGLE
|
25 |
5'11" |
7'3" |
7'8" |
| TWO
|
5'11" |
7'11" |
9'0" |
| THREE
|
6'7" |
8'10" |
9'3" |
| SINGLE
|
30 |
5'5" |
6'9" |
7'2" |
| 5'5"
|
7'3" |
8'2" |
6'3" |
| THREE
|
6'0" |
8'1" |
8'10" |
| SINGLE
|
35 |
5'0" |
6'5" |
6'10" |
| TWO
|
4'10" |
6'9" |
7'7" |
| THREE
|
5'6" |
7'6" |
8'5" |
| SINGLE
|
40 |
4'8" |
6'2" |
6'6" |
| TWO
|
4'3" |
6'3" |
7'1" |
| THREE
|
4'10" |
7'0" |
7'11" |
| SINGLE
|
50 |
4'2" |
5'7" |
6'1" |
| TWO
|
3'4" |
5'1" |
5'11" |
| THREE
|
3'10" |
5'9" |
6'9" |
|
| Contact Enduro for
SERIES FM Loads/Span Data |
| |
|
Load/Span Tables are
based on full scale tests that consider three design parameters:
- Critical bending
moment at actual panel failure
- Flexural stiffness
- Pullover force
per fastener of the panel section.
Table values are based
upon:
- Roofing:
Deflection l/60, FOS 2.5+, 1.88-
- Siding:
Deflection L/30 FOS 1.88
|
| |
|
|
| |
|
|
| |
|
The load/span tables
shown in this Guide are derived from large scale tests using full panels
to simulate actual service conditions (at a reference temperature of 77°
F). These tests include two span vacuum box test and three point load
tests.
Each span shown in the load/span tables represents the most conservative
span derived when the panel is assessed using the following parameters:
Design Parameters
- Critical bending
moment at actual panel failure;
- Flexural stiffness
factor, EI, (where E is the flexural
modulus of elasticity and I is the moment of inertia of
the panel section); and
- Pullover force
resistance per fastener.
|
|
|
| |
The load/span tables
shown in this Guide are developed using the following maximum deflections
limits and Factors of Safety (FOS), unless otherwise noted:
Panel Roofing:
Positive Loads: Deflection: L/60, FOS:2.5
Negative Loads: Deflection: L/60, FOS: 1.88
Panel Siding:
Wind Loads: Deflection: L/30, FOS:1.88
Roof Deck:
Dead + Live Loads: Deflection: L/180, FOS:2.5 Uplift Loads: Deflection:
L/18000, FOS:1.88
The load/span tables are to be used as a guide only as specific environmental
conditions are not considered.
Specific applications should be verified by a registered Professional Engineer.
|